Shall be a Crown models,
convection steamer on a modular steam coil boiler base. The steamer
shall be constructed of satin finish stainless steel, type 304, with a
cooking chamber of one-piece, all-welded, type 316 stainless steel
and shall be
SCX-2, 14” W x 10.625” H x 21 D (355 mm x 270 mm x 533 mm).
SCX-10, 14” W x 17” H x 21 D (355 mm x 432 mm x 533 mm).
The doors shall have a removable inner liner of stainless steel with full
perimeter gasket seal, an outer liner of one-piece all welded stainless
steel, and a positive lock and seal mechanism with spring release. The
steamer shall be provided with removable stainless steel pan supports
and a stainless steel drip trough connected to drain in order to collect
condensate when door is opened.
Each compartment’s control housing shall be constructed of stainless
steel with a fully removable side access panel. The controls shall include
an illuminated on/off power switch. The timing of each compartment
shall be independently controlled by a pilot ready light, a pilot cooking
light and a 60 minute electric timer which sounds an audible signal
at the end of the cooking cycle. Steam flow to the chamber shall be
cut off when the door is opened during the cooking cycle and shall be
reactivated when the door is closed.
The cabinet base with steam coil boiler and controls shall be provided
with full perimeter painted angle frame, reinforced counter and boiler
mountings, hinged door(s) with magnetic latch and 6” (152 mm) stainless
steel legs with 4 adjustable flanged feet for securing to the floor.
Boiler controls shall include automatic water level control, pressure
gauge, water gauge glass, operating pressure control, safety highlimit pressure control and safety relief valve. Unit comes standard with
a water treatment system, split water line, and automatic blowdown.
The unit shall be ASME code stamped and National Board registere,
c-CSA-us and NSF certified.