Reverse Osmosis System, 300 gallon atmospheric storage tank, up to 1500 gpd production, integrated triple/parallel prefilters protect the pump-pressurized RO membrane, Mineral-Addition cartridge, dual‐read digital TDS meter displays RO membrane performance and optimized water quality, built‐in full system bypass valve, adjustable reject flow control, storage tank has sub-micron air breather, 1 HP floor-mounted repressurization pump, 16 gallon buffer tank assembly, designed for multiple point-of-use applications where up to 10 gpm combined flow to equipment is required, includes hose, tubing & fittings required for installation (164‐15580)
   

Model: BWS1500/300 HF

     

Part #: 164-15580

   

ITEM #:

QTY:

 
 

Snapshot

JOB NAME/NUMBER:

           

The OptiPure ® BWS1500/300 HF Water Treatment System utilizes Reverse Osmosis (RO) to remove >97% of the Total Dissolved Solids (TDS) from water. Then,

         

a

balance of minerals is dissolved into the RO water,

         

followed by a precision blend valve for further TDS adjustment, to provide desirable optimized water TDS. The system is pump-driven and will produce up to 1500-gallons per day of optimal quality water for applications where TDS reduction or the removal of the majority of hardness minerals is required. This

         

complete system includes integrated pre-filtration with particulate and chlorine reduction, reverse osmosis, blend valve and mineral addition, in a space saving, wall-mounted design. Adjustable reject flow control allows precise adjustment of product/reject ratio.

         

A

built-in full system bypass valve and sample port

         

assures no service interruption and simplifies routine maintenance. Also included is a 300-gallon atmospheric storage tank (with a sub-micron air breather) with a 1 hp floor-mounted repressurization pump, a 16-gallon buffer tank assembly and a 1/2” outlet that allows for high-flow applications. Hose, tubing and fittings required for installation are included.

         
   

Application

       
 

System Benefits

Any foodservice equipment where it is desirable to remove existing Total Dissolved Solids (TDS) and provide a consistent balance of buffered TDS.

Significantly reduces scale and corrosion problems related to high TDS, water hardness and chlorides.

Designed for multiple point-of-use applications where up to 10.0 gpm flow is required.

High flow delivery system for high demand applications.

         

Microprocessor controller provides system status and pump time-delay on start-up for pump protection.

Rotary vane pressure pump assures consistent production.

Adjustable reject flow control minimizes water use due to seasonal fluctuations in water temperature.

Precision blending valve allows the user to accurately and precisely blend a calculated amount of filtered water with the RO product water.

Digital before and after TDS meter for push-button monitoring of membrane performance and optimized water quality.

Sample port enables quick and simple system checks and adjustments.

Built-in pressure gauge allows visual monitoring of operating pressure.

Integrated system bypass valve eliminates down-time or service interruptions.

All consumables are easy-to-change Qwik-Twist cartridges.

Installation Tips

Feed-water connection to system should be COLD only.

Do not exceed system specifications for temperature and pressure.

Provide a dedicated water line of at least 1/2” I.D. to the unit for consistent flow and pressure to the system.

Allow 3” clearance below system for filter cartridge removal and replacement.

Connect filtered water line to steam production connections only. Do not use for condenser water.

Detailed installation, operation and maintenance manual included with each system.

Mount the unit where it can be easily viewed and accessed.

Water Processor Assembly - 120V

Buffer Tank
Feed-Water Chemistry
Storage Tank Assembly
Feed TDS
Up to 1200 ppm
Feed pH
6-10 units
Hardness*
12 grains or less
Free Chlorine
<2 mg/l
Iron
0.1
mg/l max
Turbidity
0.05
NTU
Manganese
0.05
mg/l max
Hydrogen Sulfide
0.0 mg/l
*For water outside of these parameters
call OptiPure technical service.
WARNING:
Cancer and Reproductive Harm -
www.P65Warnings.ca.gov.
Repressurization
Pump - 120V
Warranty
All system components and assembly except for filter cartridges, separation membranes, permeate
pumps, electric motors, diaphragm pumps, and rotary vane pumps shall be warranted against
defects in workmanship for a period of 60 months from the date of original shipment. For complete
warranty information, contact OptiPure customer service or go to www.optipurewater.com.

Model: BWS1500/300 HF

Part #: 164-15580

Specifications

System

 

Dimensions - RO Processor

33.6”h x 30.1”w x 9.1”d

Dimensions - Tank

79.9”h x 35.6” dia.

Dimensions - Buffer Tank

30.4”h x 15.6”dia.

Connection - Feedwater

1/2” Push Fit Tubing

Operating Pressure Range

30 - 90 psi at 2.5 gpm (2.1 - 6.2 bar)

Inlet Water Temperature Range

40˚ - 100˚F (4˚ - 38˚C)

Shipping Weight

320 lbs.

Drain Connection

5.0 gpm Minimum Flow

Power - Water Processor

120V 60Hz 6W

Power - Repressurization Pump

120V 60Hz 2W

Performance

 

Typical TDS Rejection

>97%

Product Water Production

1,500 gals./day

(at 77 o F, 60 psi Net Operating Pressure) Production rate is strictly dependent on feed water temperature and pressure.

62 gals./hr

1.0 gpm

Replacement Media

 

Model

Description

Part Number

Qty

CTO-Q

Pre-Filter

300-05830

3

AMS-QT4021XLE

Membrane

204-44021

1

MA-Q15

Post-Filter

300-05855

1

Options

 

Model

Description

Part Number

Air-Gap Kit

Approved Air-Gap Kit for Drain Line

164-89905

FXPT-11CR

Chloramine Reduction System

160-50011

Remote Kit

Repressurization/Storage Tank Assembly

164-89116

It is recommended that pre/post-filters and mineral addition cartridges are changed every 6 months, when capacity is reached or when feedwater pressure or flow becomes inadequate.

Membrane life varies depending on feedwater conditions and pre-filter maintenance. It is 12-18 months under typical conditions, but it can be as long as 3-5 years.

This product is for commercial use only and must be installed and maintained according to manufacturer’s guidelines.

Do not use on water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Dealer/Distributor Info:

 

OptiPure, A Division of Aquion, Inc.

101 S. Gary Ave., Suite A Roselle, IL 60172 p: 972.881.9797 e: [email protected] www.optipurewater.com

BWS1500/300 HF_Spec _R3

091218

Part #: 164-15580

Model: BWS1500/300 HF

Equipment

1/2” HOSE

Out to

Installation Diagram

Feed Water
(Optional)
Air
Gap
at
Drain

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality