Recently added item(s) ×

You have no items in your shopping cart.

Se Habla Español (877) 254-5449 Store Hours: (M-F) 9am-5pm CST/ (Sat) 10am-2pm Call Center Hours: 8am-10pm CST/ (7days/week)

Pitco Frialator VF-35S Full Pot Floor Model Gas Fryer

Manufacturer Sku:PIT-VF-35S

Pitco Frialator VF-35S Full Pot Floor Model Gas Fryer

  • Manufacturer Sku: VF-35S
  • Weight: 155.0000
  • Manufacturer: Pitco Frialator
  • Width: 15.63
  • Height: 47.25
  • Depth: 32.00
Item:
PIT-VF-35S

Features :

  • Fryer
  • gas
  • tube fired stand alone model
  • 35 lb. oil capacity
  • millivolt control
  • removable basket hanger
  • includes (2) twin baskets
  • 9" adjustable legs
  • stainless steel tank
  • front
  • door & sides
  • 70
  • 000 BTU
  • ENERGY STAR®
  • CSA Flame
  • CSA Star
  • NSF
  • CE


 Spec Sheet
 Owner's Manual

Value Fryer Series Models VF35 & VF65

Value Fryer Series Models VF35 & VF65

STANDARD ACCESSORIES

Tank-stainless steel

Cabinet - stainless front, door and sides

One tube rack

One built-in flue deflector

Two twin size baskets

One drain extension

One drain line clean-out rod

Removable basket hanger for easy cleaning

9”(22.9cm) adjustable legs, easier access to clean

AVAILABLE OPTIONS & ACCESSORIES

Tank Cover

9”(22.9cm) Casters

Project

Item No

Quantity

STANDARD SPECIFICATIONS

CONSTRUCTION

Welded tank with an extra smooth peened finish ensures easy cleaning.

Long lasting, high temperature alloy stainless steel heat baffles are mounted in the heat exchanger tubes to provide maximum heating and combustion.

Standing pilot light design provides a ready flame when heat is required.

Stainless steel front, door, sides and splash back.

CONTROLS

Solstice burner/baffle design. -Increases cooking production -Lowers flue temperature -Improves working environment -Generates more production per BTU

Thermostat maintains selected temperature automatically between 200°F (93°C) and 400°F (190°C).

Integrated gas control valve acts as a manual and pilot valve, automatic pilot valve, gas filter, pressure regulator, and automatic main valve.

Gas control valve prevents gas flow to the main burner until pilot is established and shuts off all gas flow automatically if the pilot flame goes out.

Temperature limit switch safely shuts off all gas flow if the fryer temperature exceeds the upper limit.

OPERATIONS

Front 1-1/4" NPT drain valve, for quick draining

Pitco Frialator, Inc P.O. Box 501, Concord, NH 03302-0501 553 Route 3A, Bow, NH 03304 603-225-6684 FAX: 603-225-8497 www.pitco.com

L10-347 Rev 5

06/19

Printed in the USA

Value Fryer Series Models VF35 & VF65

Value Fryer Series Models VF35 & VF65

TABLE
A
BCDEF
GHJ
15
5/8
14 1/2
7
13/16
19 5/8
15
1/8
14.0
32.0
22
3/4
46 5/16
VF35
[39.7]
[36.8]
[19.8]
[49.8]
[38.4]
[35.6]
[81.3]
[57.8]
[115.0]
19
5/8
17 11/32
9
13/16
17 11/32
12
5/16
18.0
34.0
24
3/4
52 17/64
VF65
[49.8]
[44.1]
[24.9]
[44.1]
[31.2]
[45.7]
[86.3]
[62.8]
[132.7]
3/4" NPT GAS CONNECTION.
B
1-1/4" NPT (3.2 cm)
FULL PORT DRAIN VALVE
F
J
A
INTEGRAL FLUE DEFLECTOR
13
G
1 16 [4.6]
INCHES [CM]
5
[1.6]
8
1
47 4 [120.0]
34 [86.4]
G
NOM.
D
1
D
15 16 [38.2]
E
9 [22.9]
NOM.
9
1
16 [4.0]
2X 1 25 [4.5]
C
32
23
H
4
[12.0]
32
 

INDIVIDUAL FRYER SPECIFICATIONS

 

Model

 

Frying Area

 

Cook Depth

 

Oil Capacity

 

Gas Input Rate / Hr

 

Burner Pressure Nat

 

Burner Pressure LP

   

14

x 14 in

   

2.0

- 3.5 in

   

35

- 40 Lbs

70,000 BTU (CE 20.5 kW) (AU 74 MJ)

   

VF35

(35.6 x 35.6 cm)

(5.0 - 8.0 cm)

(15.9 - 18.1 liters)

 

4" W.C.

 

10" W.C. (25 mbars / 2.4 kPa)

   

18

x 18 in

   

3.0

- 5.0 in

   

65

- 80 Lbs

95,000 BTU (CE 26.5 kW) (AU 95 MJ)

 

(10 mbars / 1 kPa)

 

VF65

(45.7 x 45.7 cm)

(8 - 13 cm)

(31 - 39 liters)

   

Model

 

Shipping Weight

   

Shipping Crate Size H x W x L

   

Shipping Cube

 

VF35

 

155

Lbs (70.3 kg)

   

36 x 19 x 46 in

(116.8 x 48.3 x 91.4 cm)

   

18.2 ft 3 (0.5 m 3 )

 

VF65

 

180

Lbs (81.6 kg)

 
   

INSTALLATION INFORMATION

 
 

GAS SYSTEM REQUIREMENTS

   

Total Gas Load / Hr

 
     

Natural Gas

   

LP Gas

   

VF35

70,000 BTU, (CE 20.5kW), (AU 74 MJ)

 

Supply Pressure *

 

7 - 10" W.C.

   

11 - 13" W.C.

   

VF65

95,000 BTU, (CE 26.5kW), (AU 95 MJ)

 
 

(17.4 mbars/ 1.74 kPa)

(27.4 mbars/ 2.74 kPa)

 
 

* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.

 
   

CLEARANCES

 

Front min.

Floor min.

 

Combustible material

 

Non-Combustible material

 

Fryer Flue Area

 

30"

 

6"

 

Sides min.

Rear min.

Sides min.

Rear min.

Do not block / restrict flue gases from flowing into hood or install vent hood drains over the flue.

(76.2 cm)

(15.25 cm)

6" (15.2 cm)

6" (15.2cm)

 

0"

 

0"

 

Provide Pitco VF35 or VF65 tube-fired gas fryer.

Fryer shall have a blower free atmospheric burner system combined with three stainless steel tubes, VF65

with four stainless steel tubes, utilizing high temperature alloy stainless steel baffles, with thermostatic control, thermo-safety pilot and spark ignitor, separate gas shut off, 3/4" npt rear gas connection, recessed cabinet back, 1-1/4" Full port drain. Fryer shall have a deep cool zone; minimum 20% of total oil capacity. Model VF35 shall be a cooking area of 14" x 14". Model VF65 shall be a cooking area of 18" x 18".

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Quality