Pre-plumbed for externally-mounted third party ANSUL® system
Interlock system disables appliances if filters are missing or
clogged or in the case of a fire
Completely self-contained filtration process reduces emissions
below that allowed in NFPA 96 and ANSI UL 710B using the EPA
202 test method
Airflow sensors continually monitor airflow to optimize
performance and grease removal
Illuminated early-warning system to monitor filter replacement
status
Two [2] LED lights producing 990 lumens for uncompromised
under hood visibility
Rear and side knockouts to allow for easy electrical connections
to any type of unit
Quiet 60 dBA operation
Non-permanent installation allows the unit to move with your
business—making for a better investment for leased spaces
and growing operations.
DESCRIPTION:
Wells universal countertop ventless hoods are certified Type-1
compliant, UL 710B approved recirculating systems and feature
a completely self-contained air filtration system. These eliminate
the need for exterior venting, making it possible to cook in
non-traditional locations or when traditional Type-1 hoods and
ductwork are impractical, restricted, or too expensive. These will
accommodate various electric cooking equipment including fryers,
ovens, griddles, etc. providing maximum flexibility.
SPECIFICATIONS:
The WVU-31CT will be constructed with a stainless steel body. All
units will come ANSUL® ready and include factory installed piping,
five [5] discharge nozzles, electronic heat sensors, and will be
ready to connect to an external fire protection system. This unit
will have the ability to connect to the buildings fire alarm system.
Purchase, installation, charging, and certification will have to
be performed by a licensed ANSUL® agent [these will be the
responsibility of the user and not included in the purchase].
The completely self-contained filtration process reduces emissions
below that allowed in NFPA 96 and ANSI UL 710B using the EPA
202 test method and will include a stainless steel grease baffle
filter with grease cup, fiberglass pre-filters, HEPA (high-efficiency
particulate air) filter/carbon-charcoal filter pack. All filters are
easily removable without tools. Air flow sensors continually
monitor air flow optimizing performance and grease removal
while an interlock system will not allow cooking appliances to
function if filters are missing, clogged or in the event of a fire.
Units will use 208 V/240 V service.