
Online Shopping!
Delivery & Pickup
Brand
Price
The highest Price is
$1,389.13
Width
The highest Width is
9999 inch
Certifications
Delivery & Pickup
Brand
Price
The highest Price is
$1,389.13
Width
The highest Width is
9999 inch
Certifications

Fisher 3990 Atmospheric Vacuum Breaker, 45° Ledge Mount, 1/2" M Inlet
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Fisher 2932-8002 Vacuum Breaker Assembly, Atmospheric, 3/8", Chrome Plated Brass
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Krowne 21-450L Vacuum Breaker For Royal Series Faucets, Up To 210°F, Low Lead Compliant
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 561142 Vacuum Breaker – Replaces Jackson 184301, Blakeslee 05913
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Fisher 2935-8000 Vacuum Breaker Assembly, Atmospheric, 3/4" F Inlet & Outlet
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Krowne 21-455L Vacuum Breaker Assembly, "U" Shaped, 6" Centers, 1/2" NPT Male Threads
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 561341 Vacuum Breaker - 1/2" NPT Brass, Conbraco – Replaces Champion 100500, Insinger D-2241
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Fisher 2932-8000 Vacuum Breaker Assembly, Atmospheric, 1/4" F Inlet & Outlet
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 561342 Vacuum Breaker – 3/4" NPT Brass Valve, 125 PSI, 212°F Rating, Conbraco for Kitchen
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Fisher 14443 Pressure Vacuum Breaker, 1/2" F Inlet & Outlet, Anti-Spill
You can only compare up to 4 items.
Remove items from compare bar below to add more.

T&S Brass 5PR-VB Equip Dual Check Vacuum Breaker, 3/8" NPT Inlet & Outlet, Close Nipple, Low Lead
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 561343 Vacuum Breaker - 3/4" NPT Valve – Replaces Stero 0P-151149, 0P-621149
You can only compare up to 4 items.
Remove items from compare bar below to add more.

Fisher 14540 Pressure Vacuum Breaker, 1/2" F Inlet & Outlet, Wall-Mounted
You can only compare up to 4 items.
Remove items from compare bar below to add more.

T&S Brass B-0970-01 Atmospheric Vacuum Breaker Assembly, 3/8" NPT Inlet & Outlet, With Adapters
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 511484 Vacuum Breaker Kit, 3/4" Conbraco – Replaces Champion 108351, Jackson 04820-200-23-00
You can only compare up to 4 items.
Remove items from compare bar below to add more.

T&S Brass B-0965 Atmospheric Vacuum Breaker Assembly, 1/2" IPS Inlet, 3/8" IPS Outlet, Chrome-Plated
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 511137 Vacuum Breaker Repair Kit - 3/8" NPT, Disk Float & O‑Ring, Commercial Plumbing Part
You can only compare up to 4 items.
Remove items from compare bar below to add more.

T&S Brass B-0929-A Vacuum Breaker Assembly, All Brass, Heavily Chromium Plated
You can only compare up to 4 items.
Remove items from compare bar below to add more.

AllPoints 1412227 Vacuum Breaker Repair Kit, Friction Ring, Sack, Baffle – OEM Sloan 3323192
You can only compare up to 4 items.
Remove items from compare bar below to add more.

T&S Brass B-0929 Vacuum Breaker Assembly, All Brass, Heavily Chromium Plated
You can only compare up to 4 items.
Remove items from compare bar below to add more.
A vacuum breaker is a backflow preventer usually mounted near the water source before running into the spout. A hose submerged into a mop bucket or a warewashing sink full of contaminated water may pose serious health hazards. The water in such containers must in no way siphon back into the potable water supply. With a simple device attached to your faucet or hose thread, it is possible to safeguard your water system against back-siphonage.
A commercial kitchen is awash with sinks dispensing water for washing, sanitizing, and food preparation tasks. Continuous pressure applications and cross-connections in such workspaces pave the way for the backflow of dirty or detergent water. A vacuum breaker is one of several types of backflow preventers to avoid back-siphonage incidents.
Atmospheric vacuum breakers are among the simplest and the most inexpensive backflow preventers. They are composed of a check valve and an air vent, and the outside air pressure pushes the valve and closes it when the water is off.
Pressure vacuum breakers are a variation of the atmospheric type. The difference is that their check valve features a spring. The spring pushes the valve open to the atmosphere and blocks the pipe when water pressure is low. Hose connection vacuum breakers are threaded tools that screw on each hose bibb or faucet in your kitchen.
Codes about backflow prevention may vary, so it is advisable to check the plumbing regulations that apply to your state. This is crucial for deciding on the type and installation of the vacuum breakers you might need. Are you leaving hoses in mop buckets or sinks filled with chemicals? It is a moral responsibility to take preventive measures against backflow no matter what the codes demand.
Whether retrofitting or remodeling your kitchen, you need a vacuum preventer to protect your potable water supply. Plus, add a vacuum breaker repair kit into your shopping cart to fix possible faults.