Cleveland KGL40PQS Stationary Gas Kettle
Standard Features
- High efficiency Power Burner Heating System (62% to 65% efficiency)
- Fast Heat-up and Recovery Time, 140M BTU’s on 40 gallon models, 190M BTU’s on 60 gallon and larger
- Insulated Heat Exchanger
- Automatic Ignition System
- Steam jacket permanently filled with treated, distilled water. Venting and/or refilling not required
- Solid State Controls, for Temperature and Low Water Safety, in a plug-in Control Module
- Control Panel includes: - Precise, consistent temperature control: less than ± 1°C variance (ideal for simmering). - L.E.D. Indicators for Heat Cycle and Low Water - Warning. - Power “on/off” Switch
- Front mounted combination Pressure/Vacuum Gauge
- Type 316 Stainless Steel with #4 finish on kettle
- 2˝ diameter Tangent Draw-Off Valve with Drain Strainer
- Support Legs with level adjustable feet, flanged for floor bolting
- Spring-assisted, hinged, rotatable, domed Stainless Steel Cover
- 50 PSI Steam Jacket Rating and Safety valve
- Standard voltage is 115 volts, 60 Hz, single-phase, supplied with cord and plug
- Standard for natural gas operation
- Faucet Mounting Bracket (FBK)
- Typical approvals include AGA, CSA, CE, NSF and ASME
From The Manufacturer
(Quickship) Kettle, natural gas, stationary, 40-gallon capacity, 2/3 steam jacket, 316 stainless steel interior, self-contained, floor mounted control console supports, electronic ignition, 304 stainless steel finish, faucet mounting bracket, flanged feet, 2" tangent draw-off with strainer, spring-assisted cover, 50 psi rating, 140,000 BTU, 120v/60/1-ph